How to Troubleshoot Triplex Plunger Pumps
Detach the electrical connection of the pump: It is highly dangerous to attend a plunger pump that is being supplied with electrical power., Check the nozzle of the pump: In many cases, after prolonged use of the pump, its nozzle gets worn out and...
Step-by-Step Guide
-
Step 1: Detach the electrical connection of the pump: It is highly dangerous to attend a plunger pump that is being supplied with electrical power.
Thus first and foremost, you must detach the power connection of the pump and then examine it for flaws or glitches. , In order to rectify this issue, all you need to do is disassemble the old nozzles from the pump and replace them with the new ones., Cavitation can lead to immensely low pressure causing the pump to not function properly.
In order to troubleshoot this problem, you should increase the input of water in the pump to create substantial pressure and get rid of the air cavities., This could cause the brass covering to get adversely affected and come off altogether from the pump.
You can solve this issue by simply readjusting the unloader valve.
In case of a broken connector rod, get it replaced with a new one., You need to replace the old, malfunctioning gauge with a new one so as to make your pumps work properly.
All you need to do is unscrew the pressure gauge, disassemble it from the pump, and install the new one in its place., Apart from keeping a regular check, you can seal the inlet with PTFE liquid or tape. -
Step 2: Check the nozzle of the pump: In many cases
-
Step 3: after prolonged use of the pump
-
Step 4: its nozzle gets worn out and it might lead to leakage or decrease in the water pressure.
-
Step 5: Rectify the cavitation problem: It may happen that there is cavitation in your triplex plunger pump because of lesser water supply or damaged interiors.
-
Step 6: Check the unloader valve adjustments: If the unloader valve of a triplex plunger pump is not adjusted properly
-
Step 7: then it might lead to sudden bouts of high pressure in the pump.
-
Step 8: Replace the malfunctioning pressure gauge: Any expert in the piping industry will vouch for the importance of gauge plugs.
-
Step 9: Check the inlet for any air leaks: Another common issue with the triplex plunger pumps is the chances of air leakage near the inlet.
Detailed Guide
Thus first and foremost, you must detach the power connection of the pump and then examine it for flaws or glitches. , In order to rectify this issue, all you need to do is disassemble the old nozzles from the pump and replace them with the new ones., Cavitation can lead to immensely low pressure causing the pump to not function properly.
In order to troubleshoot this problem, you should increase the input of water in the pump to create substantial pressure and get rid of the air cavities., This could cause the brass covering to get adversely affected and come off altogether from the pump.
You can solve this issue by simply readjusting the unloader valve.
In case of a broken connector rod, get it replaced with a new one., You need to replace the old, malfunctioning gauge with a new one so as to make your pumps work properly.
All you need to do is unscrew the pressure gauge, disassemble it from the pump, and install the new one in its place., Apart from keeping a regular check, you can seal the inlet with PTFE liquid or tape.
About the Author
Patrick Powell
A seasoned expert in education and learning, Patrick Powell combines 5 years of experience with a passion for teaching. Patrick's guides are known for their clarity and practical value.
Rate This Guide
How helpful was this guide? Click to rate: